產品說明
DeskTop Adapter
Our FRA018 series is comply with latest standard IEC/EN/UL 62368-1 and 60950-1 which is suitable for I.T. and audio equipment. We have 12~18W AC laptop power adapter with 5V~50V wide output voltage range for this series. Also it is comply with energy efficiency level VI and ErP Tier 2. No load power consumption < 0.075W with high effiency. It's flexible for new design or replace for the old product.功能說明
- Anywhere output voltage 5 ~ 50 VDC
- Universal Input, Desktop Adaptor
- Interchangeable plug type available
- Meet CEC level VI
規格
Input Voltage | 90 ~ 264 VAC |
Inrush Current | 0.7 A Max. |
Input Frequency | 47 ~ 63 Hz |
Efficiency | 82% typ. @ full load |
Output Voltage | (anywhere output voltage) 5 ~ 50 VDC |
Voltage Regulation | ± 5% max |
Operating Temperature | -10℃ ~ +60℃ (derated linearly from 100% load @ 40℃ to 50% load @ 60℃) |
Storage Temperature | -20°C ~ +85°C |
Protections | OVP, OLP, Short Circuit Protection |
Safety Standard | UL60950-1/62368-1, EN60950-1/62368-1, CE, CB |
EMC Standard | (EN55032, CISPR 22, FCC Part 15) Class B EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55035 |
Standard Output Connector | DC Barrel Jack |
Standard Output Cable/Length | UL1185 / 1M |
Size | L82 x W43.5 x H35.7 mm |
Model
Model No. | I/P Vol. | O/P Vol. | O/P Current | O/P Watts (max.) | DoE 6 | CoC 5 | Ecodesign |
FRA018-S05-x | 90~264VAC | 5.00 VDC | 2.40A | 12W | VI | Tier 2 | 2019/1782 |
FRA018-S05-x1 | 5.40 VDC | 2.22A | |||||
FRA018-S07-x | 90~264VAC | 5.99 VDC | 2.00A | 12W | VI | Tier 2 | 2019/1782 |
FRA018-S07-x1 | 7.00 VDC | 1.86A | 13W | Tier 1 | |||
FRA018-S07-x2 | 7.50 VDC | 1.73A | Tier 2 | ||||
FRA018-S09-x | 90~264VAC | 8.00 VDC | 2.25A | 18W | VI | Tier 2 | 2019/1782 |
FRA018-S09-x1 | 9.00 VDC | 2.00A | |||||
FRA018-S09-x2 | 10.0 VDC | 1.80A | |||||
FRA018-S12-x | 90~264VAC | 12.0 VDC | 1.50A | 18W | VI | Tier 2 | 2019/1782 |
FRA018-S15-x | 90~264VAC | 13.6 VDC | 1.32A | 18W | VI | Tier 2 | 2019/1782 |
FRA018-S15-x1 | 14.4 VDC | 1.25A | |||||
FRA018-S15-x2 | 15.0 VDC | 1.20A | |||||
FRA018-S18-x | 90~264VAC | 16.5 VDC | 1.09A | 18W | VI | Tier 2 | 2019/1782 |
FRA018-S18-x1 | 18.0 VDC | 1.00A | |||||
FRA018-S18-x2 | 20.0 VDC | 0.90A | |||||
FRA018-S24-x | 90~264VAC | 24.0 VDC | 0.75A | 18W | VI | Tier 2 | 2019/1782 |
FRA018-S30-x | 90~264VAC | 27.0 VDC | 0.67A | 18W | VI | Tier 2 | 2019/1782 |
FRA018-S30-x1 | 27.6 VDC | 0.65A | |||||
FRA018-S30-x2 | 30.0 VDC | 0.60A | |||||
FRA018-S36-x | 90~264VAC | 33.0 VDC | 0.55A | 18W | VI | Tier 2 | 2019/1782 |
FRA018-S36-x1 | 36.0 VDC | 0.50A | |||||
FRA018-S48-x | 90~264VAC | 48.0 VDC | 0.38A | 18W | VI | Tier 2 | 2019/1782 |
Notices:
- FRA018-S05-x : output voltage from 5~6VDC is available
- FRA018-S07-x : output voltage from 6~8VDC is available
- FRA018-S09-x : output voltage from 8~11VDC is available
- FRA018-S12-x : output voltage from 11~13VDC is available
- FRA018-S15-x : output voltage from 13~16VDC is available
- FRA018-S18-x : output voltage from 16~21VDC is available
- FRA018-S24-x : output voltage from 21~27VDC is available
- FRA018-S30-x : output voltage from 27~33VDC is available
- FRA018-S36-x : output voltage from 33~40VDC is available
- FRA018-S48-x : output voltage from 40~50VDC is available
Ordering Information:
- Those items with CEC level VI compliance are also compliant to ErP Tier 2
- CEC compliance model standby power @ no load < 0.075W
- Note: x = Inlet Type Code,
x = 4 (IEC320 C14) ; x = 6 (IEC320 C6) ; x = 8 (IEC320 C8)