100 WATT Single Output MEDICAL POWER SUPPLIES : FPM100
FPM100 - 100 WATT Single Output MEDICAL POWER SUPPLIES
Description
Medical Open Frame
The FPM100 series of compact, open PCB constructed, AC-DC switching power supplies are capable of delivering 100 watts of continuous output power at convection cooling. They are suited for medical applications. Approval to UL60601-1 safety standard improves design-in time and reduces end equipment compliance costs.Features
- Medical approvals
- Compact size 2”×4”×1.26”
- High power density 10 W/cubic inch
- 100W output with convection cooling up to +50℃
- Low earth leakage current
- EN55011 /55022 class B emissions
- RoHS compliant
Specification
Input voltage | 90-132 /180-264 VAC (Universal mains supply operation) |
Input frequency | 47-63 Hz |
Input current | 1.9 A (rms) for 100-120 VAC ; 1.1 A (rms) for 200-240 VAC |
Earth leakage current | 150 μA max. @ 264 VAC, 63 Hz |
Touch current | 100 μA max. @ 264 VAC, 63 Hz |
Output voltage/current | See rating chart. |
Total output power | 100 watts maximum |
Ripple and noise | 150 mV peak to peak on 5.0 V model, 1% peak to peak on other models |
Overvoltage protection | Provided on output; set at 110-140% of its nominal output voltage |
Overcurrent protection | All outputs protected to short circuit conditions |
Temperature coefficient | All outputs ±0.04% /℃ maximum |
Transient response | Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500 us after a 25% step load change |
Operating temperature | -10℃ to +70℃ |
Storage temperature | -40℃ to +85℃ |
Relative humidity | 5% to 95% non-condensing |
Derating | Derate from 100% at +50℃ linearly to 50% at +70℃ |
Cooling | Convection |
Switching frequency | 100 KHz (typical) |
Efficiency | 88-90% @ 230 VAC full load |
Hold-up time | 12 ms minimum at 110 VAC |
Line regulation | ±0.2% maximum at full load |
Inrush current | 40 A @ 115 VAC or 80 A @ 230 VAC, at 25℃ cold start |
Withstand voltage | 5600 VDC from input to output (2 MOPP) ; 2100 VDC from input to ground (1 MOPP) ; 700 VDC from output to ground(To verify AC strength, get correct test method to avoid power supply damage.) |
MTBF | 270,000 hours at full load at 25℃ ambient temperature, calculated per MIL-HDBK-217F EMC Performance |
EN55011 /EN55022 | Class B conducted, class B radiated |
EN61000-3-2 | Harmonic distortion, class A |
EN61000-3-3 | Line flicker |
EN61000-4-2 | ESD, ±15 KV air and ±8 KV contact |
EN61000-4-3 | Radiated immunity, 10 V/m |
EN61000-4-4 | Fast transient/burst, ±2 KV |
EN61000-4-5 | Surge, ±1 KV diff., ±2 KV com |
EN61000-4-6 | Conducted immunity, 10 Vrms |
EN61000-4-8 | Magnetic field immunity, 30 A/m |
EN61000-4-11 | Voltage dip immunity, 30% reduction for 500 ms (criteria A @ 230 VAC, criteria B @ 100 VAC), 100% reduction for 10 ms |
Model
Model No. | I/P Vol. | O/P Vol. | O/P Current | O/P Watts(max.) |
FPM100-S050 | 90-132VAC / 180-264VAC | 5VDC | 20.00A | 100W |
FPM100-S120 | 90-132VAC / 180-264VAC | 12VDC | 8.34A | 100W |
FPM100-S150 | 90-132VAC / 180-264VAC | 15VDC | 6.70A | 100W |
FPM100-S180 | 90-132VAC / 180-264VAC | 18VDC | 5.56A | 100W |
FPM100-S240 | 90-132VAC / 180-264VAC | 24VDC | 4.20A | 100W |
FPM100-S280 | 90-132VAC / 180-264VAC | 28VDC | 3.58A | 100W |
FPM100-S360 | 90-132VAC / 180-264VAC | 36VDC | 2.78A | 100W |
FPM100-S480 | 90-132VAC / 180-264VAC | 48VDC | 2.10A | 100W |