100 WATT Single Output MEDICAL POWER SUPPLIES : FPM100

FPM100 - 100 WATT Single Output MEDICAL POWER SUPPLIES

Description

Medical Open Frame

The FPM100 series of compact, open PCB constructed, AC-DC switching power supplies are capable of delivering 100 watts of continuous output power at convection cooling. They are suited for medical applications. Approval to UL60601-1 safety standard improves design-in time and reduces end equipment compliance costs.
Features
  • Medical approvals
  • Compact size 2”×4”×1.26”
  • High power density 10 W/cubic inch
  • 100W output with convection cooling up to +50℃
  • Low earth leakage current
  • EN55011 /55022 class B emissions
  • RoHS compliant
Specification
Input voltage 90-132 /180-264 VAC (Universal mains supply operation)
Input frequency 47-63 Hz
Input current 1.9 A (rms) for 100-120 VAC ; 1.1 A (rms) for 200-240 VAC
Earth leakage current 150 μA max. @ 264 VAC, 63 Hz
Touch current 100 μA max. @ 264 VAC, 63 Hz
Output voltage/current See rating chart.
Total output power 100 watts maximum
Ripple and noise 150 mV peak to peak on 5.0 V model, 1% peak to peak on other models
Overvoltage protection Provided on output; set at 110-140% of its nominal output voltage
Overcurrent protection All outputs protected to short circuit conditions
Temperature coefficient All outputs ±0.04% /℃ maximum
Transient response Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500 us after a 25% step load change
Operating temperature -10℃ to +70℃
Storage temperature -40℃ to +85℃
Relative humidity 5% to 95% non-condensing
Derating Derate from 100% at +50℃ linearly to 50% at +70℃
Cooling Convection
Switching frequency 100 KHz (typical)
Efficiency 88-90% @ 230 VAC full load
Hold-up time 12 ms minimum at 110 VAC
Line regulation ±0.2% maximum at full load
Inrush current 40 A @ 115 VAC or 80 A @ 230 VAC, at 25℃ cold start
Withstand voltage 5600 VDC from input to output (2 MOPP) ; 2100 VDC from input to ground (1 MOPP) ; 700 VDC from output to ground(To verify AC strength, get correct test method to avoid power supply damage.)
MTBF 270,000 hours at full load at 25℃ ambient temperature, calculated per MIL-HDBK-217F
EMC Performance
EN55011 /EN55022 Class B conducted, class B radiated
EN61000-3-2 Harmonic distortion, class A
EN61000-3-3 Line flicker
EN61000-4-2 ESD, ±15 KV air and ±8 KV contact
EN61000-4-3 Radiated immunity, 10 V/m
EN61000-4-4 Fast transient/burst, ±2 KV
EN61000-4-5 Surge, ±1 KV diff., ±2 KV com
EN61000-4-6 Conducted immunity, 10 Vrms
EN61000-4-8 Magnetic field immunity, 30 A/m
EN61000-4-11 Voltage dip immunity, 30% reduction for 500 ms (criteria A @ 230 VAC, criteria B @ 100 VAC), 100% reduction for 10 ms

Model
Model No. I/P Vol. O/P Vol. O/P Current O/P Watts(max.)
FPM100-S050 90-132VAC / 180-264VAC 5VDC 20.00A 100W
FPM100-S120 90-132VAC / 180-264VAC 12VDC 8.34A 100W
FPM100-S150 90-132VAC / 180-264VAC 15VDC 6.70A 100W
FPM100-S180 90-132VAC / 180-264VAC 18VDC 5.56A 100W
FPM100-S240 90-132VAC / 180-264VAC 24VDC 4.20A 100W
FPM100-S280 90-132VAC / 180-264VAC 28VDC 3.58A 100W
FPM100-S360 90-132VAC / 180-264VAC 36VDC 2.78A 100W
FPM100-S480 90-132VAC / 180-264VAC 48VDC 2.10A 100W