1100 WATT Single Output MEDICAL POWER SUPPLIES : FPM1100

FPM1100 - 1100 WATT Single Output AC DC ENCLOSED MEDICAL POWER SUPPLIES

Description

Medical Open Frame

The FPM1100 series of AC-DC switching medical power supplies in a package of 5.91 x 9.25 x 2.4 inches are capable of delivering 1100 watts of continuous power. The units are constructed on a printed circuit board with an enclosed format for mechanical support and heat sinking. They are designed for medical applications including those needing BF rated insulation and/or an operation altitude up to 5000 meters.
Features
  • BF Class insulation
  • Operation altitude up to 5000 meters
  • Compact size 5.91” x 9.25” x 2.4”
  • Less than 300 μA leakage current
  • EN55011 Class B conducted emissions
  • Inhibit - TTL low to disable output
  • Standard PS Off and DC OK signals
  • High Efficiency 89% typical
  • Compliant with RoHS requirements
  • Standby output 5 VDC at 200 mA
  • Variable speed internal fan
  • Overvoltage protection
  • Overcurrent protection
  • Thermal protection
Specification
Input Voltage 90-264 VAC
Input frequency 47-63 Hz
Input Current (rms) 16 A (rms) @100 VAC, 60 Hz; 8 A (rms) @ 240 VAC, 50 Hz
Earth leakage current 300 μA max. @ 264 VAC, 63 Hz
Touch current 100 μA max. @ 264 VAC, 63 Hz
Ripple and noise 1% peak to peak maximum
Remote sense Compensation for cable losses up to 0.5 V
Overvoltage protection Set at 112-140% of nominal output voltage
Overcurrent protection Set at 120-140% of maximum output current
Thermal shutdown Protected to overtemperature conditions
Temperature coefficient All outputs ±0.04% /℃ maximum
Transient response Maximum excursion of 4%, recovering to 1% of final value within 500 us after a 25% step load change
Standby power 5 V at 200 mA maximum
Fan power 12 V at 1.0 A maximum
Operating temperature -10℃ to +70℃
Storage temperature -40℃ to +85℃
Relative humidity 5% to 95% non-condensing
Derating Derate from 100% at +50℃ linearly to 50% at +70℃, applicable to convection and forced-air cooling conditions
Switching frequency: 40 KHz to 200 KHz
Efficiency 88% min.
Hold-up time 10 ms minimum at 110 VAC 
Line regulation ±0.5% maximum at full load
Inrush current 50 A @ 115 VAC, or 100 A @ 230 VAC, at 25℃ cold start
Withstand voltage 4000 VAC from input to output (2MOPP); 1500 VAC from input to ground (1MOPP); 1500 VAC from output to ground
MTBF 300,000 hours at full load at 25℃ ambient, calculated per MIL-HDBK-217F
EMC Performance (IEC60601-1-2)
EN55011 Class B conducted, Class B radiated
EN61000-3-2 Harmonic distortion, Class A and D
EN61000-3-3 Line flicker
EN61000-4-2 ESD,±15 KV air and ±8 KV contact
EN61000-4-3 Radiated immunity, 10 V/m
EN61000-4-4 Fast transient/burst, ±2 KV
EN61000-4-5 Surge, ±1 KV diff.
EN61000-4-6 Conducted immunity, 10 Vrms
EN61000-4-8 Magnetic field immunity, 30 A/m
EN61000-4-11 Voltage dip immunity, 30% reduction for 500 ms, and >95% reduction for 10 ms
PFD TTL high for normal operation,low upon loss of input power, turn-on delay time 100-2500 ms, turn-off delay time 1 ms minimum
Inhibit TTL low to turn off output
DC OK TTL high when output voltage >95%
PS OFF TTL high to turn off output

Model
Model No. I/P Vol. O/P Vol. O/P Current O/P Watts (max.)
FPM1100-S240-E 90-264VAC 24 V 45.84A / 52.1 A(Peak) 1100W/1250W
FPM1100-S280-E 90-264VAC 28 V 39.29A / 44.65 A(Peak) 1100W/1250W
FPM1100-S320-E 90-264VAC 32 V 34.38A / 39.07 A(Peak) 1100W/1250W
FPM1100-S340-E 90-264VAC 34 V 32.35A / 36.77 A(Peak) 1100W/1250W
FPM1100-S360-E 90-264VAC 36 V 30.56A / 34.73 A(Peak) 1100W/1250W
FPM1100-S420-E 90-264VAC 42V 26.2A / 29.77A(Peak) 1100W/1250W
FPM1100-S480-E 90-264VAC 48 V 22.92A / 26.1 A(Peak) 1100W/1250W