20-30W fixed AC plug Wallmount Type Waterproof Adapter : FWM030 Series

FWM030 - 20~30W Medical Power Supply with configuration versatility, can be used with different fixed AC plugs as needed.

Description

Medica Waterproofl Power

The FWM030 series of AC/DC wall mount switching power supplies are for 20-30 watts of continuous output power. They are enclosed in a 94V-0 rated polycarbonate case. The FWM030 models have fixed US and Euro AC plug with IP22. All models meet EN55011 class B emission limits, and are designed for medical applications.
Features
  • Operation altitude up to 5000 meters
  • BF class insulation
  • Meet IP22
  • Overvoltage protection
  • Over-temperature protection
  • Short-circuit protection
  • 100% burn-in at full rated load
  • Compliant with DoE efficiency level VI requirements
  • Compliant with RoHS requirements
Specification
Input Voltage 80 ~ 264 VAC
Input frequency 47-63 Hz
Input Current (rms) 1.0 A (rms) for 115 VAC, 0.6 A (rms) for 230 VAC
Touch current 100μA max. @ 264 VAC, 63 Hz
Output Voltage 5 ~ 48 VDC
Maximum output power 20 ~ 30W
Efficiency 83.5 ~ 87.5%
Ripple and noise 100 ~ 480mV
Overvoltage protection 112% ~ 140%
Overcurrent protection Protected to short circuit conditions
Temperature coefficient ±0.04% /℃ maximum
Transient response Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500 us after a 25% step load change
Operating temperature -20℃ to +60℃
Storage temperature -40℃ to +85℃
Relative humidity 10% to 90% non-condensing
Temperature derating Derate from 100% at +40℃ linearly to 50% at +60℃
Hold-up time 8 ms minimum at 115 VAC
Turn on delay time 3 s maximum at 115 VAC
Efficiency Compliant with DoE efficiency level VI requirements (see rating chart)
Line regulation ±1% maximum at full load
Inrush current 60 A @ 115 VAC or 120 A @ 230 VAC at 25℃ cold start
Withstand Voltage 4000 VAC from input to output
MTBF 300,000 hours at full load at 25℃ ambient, calculated per MIL-HDBK-217F
EMC Performance (IEC 60601-1-2)
EN55011 Class B conducted, Class B radiated
EN61000-3-2 Harmonic distortion, Class A and D
EN61000-3-3 Line flicker
EN61000-4-2 ESD,±15 KV air and ±8 KV contact
EN61000-4-3 Radiated immunity, 10 V/m
EN61000-4-4 Fast transient/burst, ±2 KV
EN61000-4-5 Surge, ±1 KV diff.
EN61000-4-6 Conducted immunity, 10 Vrms
EN61000-4-8 Magnetic field immunity, 30 A/m
EN61000-4-11 Voltage dip immunity, 30% reduction for 500 ms, and >95% reduction for 10 ms

Model
Model No. I/P Vol. O/P Vol. O/P Current O/P Watts (max.) DoE 6 CoC 5
FWM030-S050-x 80-264 VAC 5.00 VDC 4.00A max. 20W VI Tier 2
FWM030-S075-x 80-264 VAC 7.50 VDC 3.00A max. 22.5W VI Tier 2
FWM030-S090-x 80-264 VAC 9.00 VDC 3.00A max. 27W VI Tier 2
FWM030-S100-x 80-264 VAC 10.0 VDC 2.70A max. 27W VI Tier 2
FWM030-S120-x 80-264 VAC 12.0 VDC 2.50A max. 30W VI Tier 2
FWM030-S150-x 80-264 VAC 15.0 VDC 2.00A max. 30W VI Tier 2
FWM030-S180-x 80-264 VAC 18.0 VDC 1.67A max. 30W VI Tier 2
FWM030-S240-x 80-264 VAC 24.0 VDC 1.25A max. 30W VI Tier 2
FWM030-S300-x 80-264 VAC 30.0 VDC 1.00A max. 30W VI Tier 2
FWM030-S480-x 80-264 VAC 48.0 VDC 0.63A max. 30W VI Tier 2

Ordering Information:

  • Note : Wall Mount AC plug Type,
    x=U (US plug) ; x=E (Euro plug)
Mechanical Drawing (Unit: mm)

Inquiry

View Picture
Selected Items
Purchasing Quantity
Purchasing Schedule
Information of Contact Person
Company Information

( Including http:// )

Inquiry Detail

By submitting your contact information, you acknowledge that you consent to our processing data in accordance with the Privacy and Cookie Policy.