2.2 KW Bidirectional Power Inverter : BIC-2200
BIC-2200 2.2 KW bidirectional power supply with energy recycle function
Description
Bidirectional Power Inverter
The BIC-2200 is a 2.2KW bidirectional power supply with enegy recycle function. It is fully digital and 1U height designed. It is designed to control the power transferred from AC grid to DC and DC to AC grid for energy recycle. The implementation of a bidirectional power supply of the BIC-2200 allows battey manufactures to charge the battery from AC grid and recycle the DC energy back into AC grid in one single unit. With built-in functions as active current sharing, remote ON/OFF control and CANBus mode available, the BIC-2200 provides vast design flexibility for battery formation & test equipment, V2G(Vehicle-to-grid) system, charging station, laser system and kinetic recovery system.Features
- 1U low profile design
- Fully digital design with 93% conversion efficiency for both AC/DC and DC/AC conversion
- Ultra-fast bidirectional time of 1ms (AC/DC ↔ DC/AC)
- CB/TUV/UL 62368-1 certified, circuit design in accordance with IEC 62477 regulation.
- Up to 5 parallel applications supported up to 11000W (4+1)
- <3% THDi in both conversion mode
- Force charging and recycle mode with CAN Bus command (Optional)
- Complete protections: Anti-islanding protection, AC anomaly protection, DC OVP, OLP, OCP, OTP
- 5-year warranty
Specification
AC to DC Direction
DC to AC Direction
AC Input Voltage Range | 180~264VAC |
Frequency Range | 47~63Hz |
Power Factor (Typ.) | 0.98/230VAC at full load |
Efficiency (Typ.) | 90~93% |
AC Current (Typ.) | 11A/230VAC |
AC Inrush Current (Typ.) | Cold start 35A/230VAC |
Leakage Current | <2mA/230VAC |
Total Harmonic Distortion | < 3%(@load=100%/230VAC) |
DC Voltage | 12V, 24V, 48V, 96V |
Rated Current | 180A, 90A, 45A, 22.5A |
Rated Power | 2160W |
Full Power Voltage Range | 12~15V, 24~28V, 48~65V, 96~112V |
Ripple & Noise (max.) | 160mVp-p, 260mVp-p, 300mVp-p, 480mVp-p |
Voltage Adj. Range | 10~15V, 19~28V, 38~65V, 76~112V |
Current Range | 0~180A, 0~90A, 0~45A, 0~22.5A |
Voltage Tolerance | +/- 1% |
Line Regulation | +/- 1% |
Load Regulation | +/- 0.5% |
Setup, Rise Time | 1800ms, 60ms/230VAC at full load |
DC to AC Direction
Rated Input Power | 1800W |
Full Power Voltage Range | 12~15V, 24~28V, 48~65V, 96~112V |
DC Voltage Range | 10~15V, 19~28V, 38~65V, 76~112V |
Max. Input Current | 150A, 75A, 37.5A, 18.75A |
Rated Output Power (Typ.)(@230V, 50Hz) | 1725A |
Voltage Range | 180~264VAC determined by AC main |
Frequency Range | 47~63Hz determined by AC main |
AC Current (Typ.) | 7.5A/230VAC |
Power Factor (Typ.) | 0.99/230VAC at full load |
Efficiency (Typ.) | 90.5~93% |
Total Harmonic Distortion | < 3%(@load = 100%/230VAC) |
O.L.P. | 105% ~ 115% Rated output power. AC to DC: Constant currrent limiting, shut down DC O/P voltage 5 sec. after DC O/P voltage is down low, re-power on to recover ; DC to AC: Not accurable with power design. |
Short Circuit Protection | Shut down O/P current, re-power on to recover. |
O.V.P. | 17.6~20.8V, 33.6~39.2V, 72.6~86V, 137.157V. Protection type: Shut down, re-power on to recover |
Over Themerature Prtection | Shut down O/P voltage, recovers automatically after temperature goes down. |
Islanding Protection | Shut sown AC O/P voltage, re-power on to recover. |
Remote ON-OFF Control | By electrical signal or dry contact. Short: Power On, Oen: Power Off. |
Bidirection Switch Time(Typ.) | 1ms |
Alarm Signal | Isolated TTL signal output for T-Alarm, DC-OK and Fault. |
Auxiliary Power | 12V@0.A tolreance +/-5%, ripple 150mVp-p. |
Battery Mode Rated Current(default) | AC to DC 160A, 80A, 40A, 20A. Can be adjusted by communication ; DC to AC 120A, 64A, 32A, 16A. Can be adjusted by communication. |
Working Temperature | -30 ~ +70℃ (refer to output derating curve) |
Working Humidity | 20~90% RH non-condensing |
Storage Temperature, Humidity | -40 ~ +85℃, 10~95% RH non-condensing |
Temperature Coefficient | +/-0.03%/℃ (0~45℃) |
Vibration | 10~500Hz, 2G 10 min./1 cycle, 60 min. each along X, Y, Z axes |
Safety standards | UL62368-1, CAN/CSA C2.2 No. 62368-1, TUV BS EN/EN62368-1, EAC TP TC 004, IEC62477-1(by request) approved. |
Withstand voltage | I/P-O/P: 3KVAC, I/P-FG: 2KVAC, O/P-FG: 500VAC |
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC / 25℃ / 70% RH |
EMC | BS EN/EN55032 ; BS EN/EN61000-3-2, 3 ; BS EN/EN61000-4-2,3,4,6,8,11 ; EN61000-6-2. |
MTBF | 155.56K hrs min. Telcordia SR-332 (Bellcore) ; 46K hrs min. MIL-HDBK-217F (25℃) |
Model
Model No. | I/P Vol. | O/P Vol. | O/P Current | O/P Watts (max.) |
BIC-2200-12 | AC180~264V / DC12V | DC12V / AC180~264V | 160A / 7.5A@230VAC | 2160W |
BIC-2200-24 | AC180~264V / DC24V | DC24V / AC180~264V | 90A / 7.5A@230VAC | 2160W |
BIC-2200-48 | AC180~264V / DC48V | DC48V / AC180~264V | 45A / 7.5A@230VAC | 2160W |
BIC-2200-96 | AC180~264V / DC96V | DC96V / AC180~264V | 22.5A / 7.5A@230VAC | 2160W |