100-150 WATT Single Output MEDICAL POWER SUPPLIES : FPM150
FPM150 - 100-150 WATT Single Output MEDICAL POWER SUPPLIES
Description
Medical Open Frame
The FPM150 series of AC-DC switching power supplies in a package of 2 x 4 x 1.3 inches are capable of delivering 100-150 watts of continuous power at 7.5 CFM forced air cooling or 100 watts at convection cooling. The units are constructed on a printed circuit board. The units are certified also toUL/CSA 60601-1. They are specially designed for medical applications.Features
- BF Class insulation
- Operation altitude up to 5000 meters
- 2 x 4 inch footprint with 1.3 inch low profile
- Less than 275 μA leakage current
- Wide input range 80-264 VAC
- Meet EN55011 /55022 Class B
- Power Factor 0.98 typical
- 100% burn-in at full load
- Short-circuit protection
- Over-temperature protection
- Power Fail Detect (PFD) signal (optional)
- Compliant with RoHS requirements
- No load power consumption less than 0.5W without PFD or 1W with PFD
Specification
Input voltage | 80-264 VAC |
Input frequency | 47-63 Hz |
Input current | 1.7 A (rms) for 115 VAC ; 0.85 A (rms) for 230 VAC |
Earth leakage current | 275 μA max. @ 264 VAC, 63 Hz |
Touch current | 100 μA max. @ 264 VAC, 63 Hz |
Output voltage/current | See rating chart. |
Total output power | See rating chart. |
Ripple and noise | See rating chart. |
Remote sense | Compensation for cable losses up to 0.5 V |
Overvoltage protection | set at 112-140% of its nominal output voltage |
Overcurrent protection | Output protected to short circuit conditions |
Temperature coefficient | All outputs ±0.04% /℃ maximum |
Transient response | Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500 us after a 25% step load change |
Fan power | 12 V at 0.5 A maximum (isolated) |
Operating temperature | 0℃ to +70℃ |
Storage temperature | -40℃ to +85℃ |
Relative humidity | 5% to 95% non-condensing |
Derating | Derate from 100% at +50℃ linearly to 50% at +70℃, applicable to convection and forced-air cooling conditions |
Switching frequency | 133 KHz (typical) |
Efficiency | See rating chart. |
Hold-up time | 10 ms minimum at 120 VAC |
Line regulation | ±0.5% maximum at full load |
Inrush current | 80 A @ 115 VAC or 160 A @ 230 VAC,at 25℃ cold start |
Withstand voltage | 4000 VAC from input to output (2 MOPP) ; 1500 VAC from input to ground (1 MOPP) ; 1500 VAC from output to ground |
MTBF | 250,000 hours at full load at 25℃ ambient, calculated per MIL-HDBK-217F EMC Performance |
EN55011/EN55022 | Class B conducted, class B radiated |
EN61000-3-2 | Harmonic distortion, class A and D |
EN61000-3-3 | Line flicker |
EN61000-4-2 | ESD, ±15 KV air and ±8 KV contact |
EN61000-4-3 | Radiated immunity, 10 V/m |
EN61000-4-4 | Fast transient/burst, ±2 KV |
EN61000-4-5 | Surge, ±1 KV diff., ±2 KV com |
EN61000-4-6 | Conducted immunity, 10 Vrms |
EN61000-4-8 | Magnetic field immunity, 30 A/m |
EN61000-4-11 | Voltage dip immunity, 30% reduction for 500 ms, 100% reduction for 10 ms |
Model
Model No. | I/P Vol. | O/P Vol. | O/P Current | O/P Watts(max.) |
FPM150-S120-z | 80-264VAC | 12V | 8.35A(Convection) / 12.50A(7.5 CFM) / 14.0A(Peak) | 100W / 150W |
FPM150-S150-z | 80-264VAC | 15V | 6.70A(Convection) / 10.00A(7.5 CFM) / 11.0A(Peak) | 100W / 150W |
FPM150-S180-z | 80-264VAC | 18V | 5.56A(Convection) / 8.34A(7.5 CFM) / 9.2A(Peak) | 100W / 150W |
FPM150-S240-z | 80-264VAC | 24V | 4.20A(Convection) / 6.25A(7.5 CFM) / 7.0A(Peak) | 100W / 150W |
FPM150-S300-z | 80-264VAC | 30V | 3.34A(Convection) / 5.00A(7.5 CFM) / 5.6A(Peak) | 100W / 150W |
FPM150-S360-z | 80-264VAC | 36V | 2.78A(Convection) / 4.17A(7.5 CFM) / 4.6A(Peak) | 100W / 150W |
FPM150-S480-z | 80-264VAC | 48V | 2.10A(Convection) / 3.13A(7.5 CFM) / 3.5A(Peak) | 100W / 150W |