72~110 Watt Medical Triple Output Power Supplies : FPM110
FPM110 - 72~110 Watt Medical Triple Output Power Supplies

Description
Medical Open Frame
The FPM110 series of compact, open PCB constructed, AC-DC switching power supplies are specially designed for medical applications. They are capable of delivering 72-110 watts of continuous power at 25 CFM forced air cooling or 60-80 watts at convection cooling. They operate at 85-264 VAC input voltage without the need of a selector strap. All models meet the safety requirements of UL, CSA for medical equipment. FPM110-zyyy x = S, D, T or Q to denote multiple output ; S for single output, D for dual output, T for triple output, Q for Quad output, yyy to denote different output rating.Features
- Low safety ground leakage current
- Meet EN55011 Class B
- Small size, light weigh
- 100% burn-in
- Wide input range 85-264VAC
- Input surge current protection
- Overvoltage protection
- Overcurrent protection
- Compliant with RoHS requirements
Specification
Input voltage | 85-264 VAC |
Input frequency | 47-63 Hz |
Input current | 3.20 A (rms) for 115 VAC ; 1.80 A (rms) for 230 VAC |
Earth leakage current | 220 μA max. @ 264 VAC, 63 Hz |
Touch current | 100 μA max. @ 264 VAC, 63 Hz |
Output voltage/current | See rating chart. |
Maximum output power | See rating chart. |
Ripple and noise | 1% peak to peak maximum |
Overvoltage protection | Provided on output #1 only; set at 112-132% of its nominal output voltage |
Overcurrent protection | All outputs protected to short circuit conditions |
Temperature coefficient | All outputs ±0.04% /℃ maximum |
Transient response | Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500 us after a 25% step load change |
PFD | TTL logic high for normal operation and TTL logic low upon loss of input power. This signal appears at least 1 ms prior to V1 output dropping 5% below its nominal value. This signal also provides a minimum delay of 100 ms after V1 is within regulation |
Operating temperature | -10℃ to +70℃ |
Storage temperature | -40℃ to +85℃ |
Relative humidity | 5% to 95% non-condensing |
Derating | Derate from 100% at +50℃ linearly to 50% at +70℃ |
Cooling | 72-110 watts continuous output power at 25 CFM forced air cooling or 60-80 watts at convection cooling |
Switching frequency | 20-250 KHz, varied with load and line |
Efficiency | 70% minimum on single output model with Vo ≧12 V, 65% minimum on the others |
Hold-up time | 12 ms minimum at 110 VAC |
Line regulation | ±0.5% maximum at full load |
Inrush current | 15 A @ 115 VAC or 30 A @ 230 VAC, at 25℃ cold start |
Withstand voltage | 5600 VDC from input to output (2 MOPP) ; 2100 VDC from input to ground (1 MOPP) ; 700 VDC from output to ground(To verify AC strength, get correct test method to avoid power supply damage.)" |
MTBF | 400,000 hours at full load at 25℃ ambient, calculated per MIL-HDBK-217F EMC Performance (EN60601-1-2) |
EN55011 | Class B conducted, class B radiated |
EN61000-3-2 | Harmonic distortion, class A |
EN61000-3-3 | Line flicker |
EN61000-4-2 | ESD, ±15 KV air and ±8 KV contact |
EN61000-4-3 | Radiated immunity, 10 V/m |
EN61000-4-4 | Fast transient/burst, ±2 KV |
EN61000-4-5 | Surge, ±1 KV diff., ±2 KV com |
EN61000-4-6 | Conducted immunity, 10 Vrms |
EN61000-4-8 | Magnetic field immunity, 30 A/m |
EN61000-4-11 | Voltage dip immunity, 30% reduction for 500 ms, 100% reduction for 10 ms |
Model
Model No. | I/P Vol. | O/P Vol. | O/P Current | O/P Watts(max.) |
FPM110-S033 | 85-264VAC | 3.3V | 0~22A | 60W / 72W |
FPM110-S050 | 85-264VAC | 5.0V | 0~22A | 80W / 110W |
FPM110-S120 | 85-264VAC | 12V | 0~9.0A | 80W / 110W |
FPM110-S150 | 85-264VAC | 15V | 0~7.5A | 80W / 110W |
FPM110-S240 | 85-264VAC | 24V | 0~4.5A | 80W / 110W |
FPM110-S300 | 85-264VAC | 30V | 0~3.6A | 80W / 110W |
FPM110-D023 | 85-264VAC | +5.1V / +12V | 0~10A/0~5A/9.0A(Ipeak) | 80W / 110W |
FPM110-T031 | 85-264VAC | +5.1V / +12V / -12V | 0~10A/0~5A/9.0A(Ipeak)/0~1A | 80W / 110W |
FPM110-T032 | 85-264VAC | +5.1V / +15V / -15V | 0~10A/0~4A/7.5A(Ipeak)/0~1A | 80W / 110W |
FPM110-Q040 | 85-264VAC | +5.1V / +12V / -12V / -5V | 0~10A/0~5A/9.0A(Ipeak)/0~1A/0~1A | 80W / 110W |
FPM110-Q041 | 85-264VAC | +5.1V / +15V / -15V / +24V | 0~10A/0~4A/7.5A(Ipeak)/0~1A/0~1A | 80W / 110W |
FPM110-Q042 | 85-264VAC | +5.1V / +12V / -12V / +12V | 0~10A/0~5A/9.0A(Ipeak)/0~1A/0~1A | 80W / 110W |
FPM110-Q045 | 85-264VAC | +5.1V / +12V / -12V / +24V | 0~10A/0~5A/9.0A(Ipeak)/0~1A/0~1A | 80W / 110W |
FPM110-Q045-1 | 85-264VAC | +5.1V / +12V / -12V / +24V | 2~10A/0~5A/9.0A(Ipeak)/0~1A/1.5~3A | 80W / 110W |
FPM110-Q045-2 | 85-264VAC | +5.1V / +24V / -12V / +12V | 0~10A/0~3A/5.0A(Ipeak)/0~1A/0~1A | 80W / 110W |
FPM110-Q046 | 85-264VAC | +5.1V / +15V / -15V / -5V | 0~10A/0~4A/7.5A(Ipeak)/0~1A/0~1A | 80W / 110W |