FranMar International Inc. continually develops the innovative FPM300 - 200-300 Watt Single Output Medical Power Supplies to meet the various market demands and bring multiple benefits to customers always. Our FPM300 - 200-300 Watt Single Output Medical Power Supplies are highly demanded by our clients across the country for optimum quality. In order to ensure longer service life and reliability, our products are manufactured by our vendors using the best quality raw material and latest technology. Whether you need a FPM300 - 200-300 Watt Single Output Medical Power Supplies, or 200-300 WATT Single Output MEDICAL POWER SUPPLIES : FPM300, FPM300 - 200-300 WATT Single Output MEDICAL POWER SUPPLIES, FPM300 - 200-300 WATT Single Output MEDICAL POWER SUPPLIES, FranMar International Inc. manufactures cost-effective products.
MEDICAL POWER SUPPLIES

200-300 Watt Single Output Medical Power Supplies : FPM300

FPM300 - 200-300 Watt Single Output Medical Power Supplies

Description :

Medical Open Frame

The FPM300 series comprising single and multiple output models for 200-300 watts of continuous output power is specially designed for medical applications. They operate at 90-264 VAC input voltage without the need of a selector strap. All auxiliary outputs are with magnetic amplifier to keep regulation. The units are constructed on a printed circuit board with a U-bracket for mechanical support and heat sinking. A cover-and-fan assembly can be added during manufacturing. FPM300-zyyy-z x = S or Q to denote multiple output ; S for single output, Q for Quad output ; yyy to denote different output rating ; z = U or E to denote different casing type ; U for U-bracket, E for Enclosed.

Features :

  • EN61000-3-2 class A and D compliant
  • Power Factor 0.98 typical
  • Overvoltage protection
  • Short-circuit protection
  • Power Fail Detect (PFD) signal
  • 100% burn-in at full rated load
  • Remote sense on output #1 and output #2
  • Remote inhibit – TTL high to disable output
  • Compliant with RoHS requirements

Specification :

Input voltage 90-264 VAC
Input frequency 47-63 Hz
Input current 4.7 A (rms) for 115 VAC ; 2.3 A (rms) for 230 VAC
Earth leakage current 300 μA max. @ 264 VAC, 63 Hz
Touch current 100 μA max. @ 264 VAC, 63 Hz
Output voltage/current See rating chart.
Maximum output power See rating chart.
Ripple and noise 2% peak to peak maximum on 3.3 V & 5.1 V and 1% peak to peak maximum on other voltage outputs
Overvoltage protection Provided on output #1 only; set at 115-140% of its nominal output voltage
Overcurrent protection All outputs protected to short circuit conditions
Temperature coefficient All outputs ±0.04% /℃ maximum
Transient response Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500 us after a 25% step load change
Fan power 12 V at 350 mA maximum for B version, 12 V at 100 mA maximum for C version
PFD TTL logic high for normal operation and TTL logic low upon loss of input power. This signal appears at least 1 ms prior to V1 output dropping 5% below its nominal value. This signal also provides a minimum delay of 100 ms after V1 output is within regulation.
Inhibit Requires an external TTL high level signal to inhibit outputs for standard models
Operating temperature 0℃ to +70℃
Storage temperature -40℃ to +85℃
Relative humidity 5% to 95% non-condensing
Derating Derate from 100% at +50℃, linearly to 50% at +70℃
Cooling 200 /250 /300 watts continuous output power at 35 CFM forced air cooling or 100 /125 /150 watts at convention cooling
Switching frequency 70 KHz ±10 KHz
Power factor 0.98 typical
Efficiency 70% minimum on all models
Hold-up time 12 ms minimum at 110 VAC
Line regulation ±0.2% maximum at full load
Inrush current 30 A @ 115 VAC or 60 A @ 230 VAC, at 25℃ cold start
Withstand voltage 5600 VDC from input to output (2 MOPP) ; 2100 VDC from input to ground (1 MOPP) ; 700 VDC from output to ground(To verify AC strength, get correct test method to avoid power supply damage.)
MTBF 300,000 hours minimum at full load at 25℃ ambient, calculated per MIL-HDBK-217F
EMC Performance (EN60601-1-2)
EN55011 Class B conducted, class B radiated
EN61000-3-2 Harmonic distortion, class A and D
EN61000-3-3 Line flicker
EN61000-4-2 ESD, ±15 KV air and ±8 KV contact
EN61000-4-3 Radiated immunity, 10 V/m
EN61000-4-4 Fast transient/burst, ±2 KV
EN61000-4-5 Surge, ±1 KV diff., ±2 KV com
EN61000-4-6 Conducted immunity, 10 Vrms
EN61000-4-8 Magnetic field immunity, 30 A/m
EN61000-4-11 Voltage dip immunity, 30% reduction for 500 ms, 100% reduction for 10 ms

Model
Model No. I/P Vol. O/P Vol. O/P Current O/P Watts(max.)
FPM300-S033-z 90-264VAC 3.3V 3.0A~60.0A 100W/200W
FPM300-S051-z 90-264VAC 5.1V 3.0A~60.0A 150W/300W
FPM300-S120-z 90-264VAC 12V 1.2A~25.0A 150W/300W
FPM300-S150-z 90-264VAC 15V 1.0A~20.0A 150W/300W
FPM300-S240-z 90-264VAC 24V 0.6A~12.5A 150W/300W
FPM300-S300-z 90-264VAC 30V 0.5A~10.0A 150W/300W
FPM300-S480-z 90-264VAC 48V 0.5A~6.3A 150W/300W
FPM300-Q040-3-z 90-264VAC 3.3V / 5.1V / 12V / 12V 3.0A~35.0A/2.0A~22A/0~4A/0~4A 125W/250W
FPM300-Q040-z 90-264VAC 5.1V / 12V / 12V / 5.1V 2.0A~35.0A/1.0A~10A/0~4A/0~4A 150W/300W
FPM300-Q041-z 90-264VAC 5.1V / 15V / 15V / 24V 2.0A~35.0A/0.8A~8A/0~4A/0~2.5A 150W/300W
FPM300-Q042-z 90-264VAC 5.1V / 12V / 12V / 12V 2.0A~35.0A/1.0A~10A/0~4A/0~4A 150W/300W
FPM300-Q045-z 90-264VAC 5.1V / 12V / 12V / 24V 2.0A~35.0A/1.0A~10A/0~4A/0~2.5A 150W/300W
FPM300-Q046-z 90-264VAC 5.1V / 12V / 12V / 15V 2.0A~35.0A/1.0A~10A/0~4A/0~4A 150W/300W
FPM300-Q047-z 90-264VAC 5.1V / 24V / 12V / 12V 2.0A~35.0A/0.5A~5A/0~4A/0~4A 150W/300W
FPM300-Q048-z 90-264VAC 5.1V / 24V / 5.1V / 15V 2.0A~35.0A/0.5A~5A/0~4A/0~4A 150W/300W
FPM300-Q049-z 90-264VAC 5.1V / 12V / 5.1V / 24V 2.0A~35.0A/1.0A~10A/0~4A/0~2.5A 150W/300W
FPM300-Q410-z 90-264VAC 24V / 12V / 5.1V / 12V 0.5A~6.3A/1.0A~10A/0~4A/0~4A 150W/300W
FPM300-Q411-z 90-264VAC 24V / 12V / 5.1V / 24V 0.5A~6.3A/1.0A~10A/0~4A/0~2.5A 150W/300W
FPM300-Q412-z 90-264VAC 24V / 12V / 12V / 12V 0.5A~6.3A/1.0A~10A/0~4A/0~4A 150W/300W
FPM300-Q413-z 90-264VAC 24V / 24V / 5.1V / 15V 0.5A~6.3A/0.5A~5A/0~4A/0~4A 150W/300W
FPM300-Q414-z 90-264VAC 24V / 24V / 12V / 12V 0.5A~6.3A/0.5A~5A/0~4A/0~4A 150W/300W

Mechanical Drawing (Unit: mm) :

Send Message
Contact Information

By submitting your contact information, you acknowledge that you consent to our processing data in accordance with the Privacy and Cookie Policy.

FranMar International Inc. is the leading supplier of FPM300 - 200-300 Watt Single Output Medical Power Supplies in Taiwan and the surrounding areas. We carry inventory all the time so you’re sure we’ll have your order ready whenever you need it. We can manufacture FPM300 - 200-300 Watt Single Output Medical Power Supplies that meet specific technical requirements. FranMar International Inc. has tailored our customer service department, product designs, technical support as well as all other company departments to serve the ultimate goal of upholding the highest standards in customer satisfaction. We appreciate the opportunity to attract your attention and value your feedback.